• Home
  • Global Solutions
  • About Us
    • Events
    • Industry Resource Links
    • Product Articles
    • Spotlight
  • Contact Us
  • +1 (386) 265-4360, (800) 888-5357
Loading


Germfree

Just another WordPress site

  • Pharmacy Equipment
    • Compounding Aseptic Isolators
    • Radiopharmacy Equipment
    • Laminar Flow Hoods
    • Biological Safety Cabinets
    • Powder Containment Enclosures
  • Class III Biosafety Cabinets
    • Advanced Engineering
    • The SEA-III
    • Aerobiology
    • All Hazard Receipt
    • Mobile & Transportable
    • Total System Integration
    • Features & Options
  • Modular Labs
    • Modular Buildings
    • Containerized Modular
    • BSL-3 HVAC Mechanical Suite
  • Mobile Labs
    • Truck Laboratories
    • Van Laboratories
    • Trailer Laboratories
    • Mobile Container Labs
    • Air/C-130 Transportable
  • Custom Cabinets & Hoods
    • Custom Biosafety Cabinets
    • Custom Fume Hoods
    • Custom Laminar Flow
    • Ventilated Workstation
  • BSL-3 Components
    • Furniture
    • Autoclaves
    • Effluent Decontamination
    • Dunk Tanks
    • Airlocks
    • Through-Wall Embeds
    • Filter Systems
    • Gas Decontamination
    • Consulting
You are here: Home / Laboratory Safety Blog / Pass Through Chamber Options in Class III BSC
Pass through chamber

Pass Through Chamber

Pass through chambers provide an easy way of moving supplies and materials in-to and out-of the Class III Biological Safety Cabinet.  There are a few options to consider with these devices.  To begin with, their interior surfaces should be coved for ease of cleaning, and the exterior of the chamber should not extend into an area where there is foot traffic.  The doors must provide an airtight seal to allow of gaseous/vapor decontamination and prevent the leakage of air from the Class III BSC into the laboratory. 

Doors should also be electronically interlocked to prevent a breach of containment.  If they are not electronically interlocked there should be either an alarm light or audible warning to let the user know when one door is open.  If they are interlocked, consideration should be given to an override switch that is positioned in a location that would require a deliberate motion for activation.  At some point pieces of equipment or tools that exceed the size of the pass through may need to be introduced or removed, hence the desire for an interlock override.  This is important if the Biological Safety Cabinet does not have an integral autoclave, or the item can not be passed out through the autoclave.

Class III Biosafety Cabinets Pass Through Chamber:  Choosing the Right Size

How do you decide what size pass through is needed?  The user(s) should take measurements of the equipment/supplies that have the greatest dimensions in terms of height, length and depth that will be used on a regular basis.  How long are the pipettes?  How tall is the animal isolator(s)?  What are the dimensions or the microfuge?  The interior measurement of the chamber when both doors are closed, should accommodate the equipment with a little room to spare. 

Class III BSC Pass Through Chamber:  Ergonomics

Size, shape and location of the pass through is also impacted by ergonomics.  Recall, the user must reach into the BSC through a gloveport and enter the pass through at a slight angle.  Items being removed must be within the users grasp, or the user will need a tool (tongs, preferably with a rubberized gripping surface) to reach further back to retrieve supplies.  Thought has to be given to what materials are in the front of the chamber near the users hand (media, samples, squeeze bottle with decontaminating solution, etc), and what can reasonably by accessed with tongs (absorbent toweling).  It is actually not so easy to get a good grip with tongs and remove pipette tips from the back of a pass through chamber.  Optimally, the user should be able to wipe down the surfaces with toweling after the chamber has been sprayed with a decontaminant.

There is no rule that says a user can only have two doors on the pass through.  Many Class III Biosafety Cabinets constructed for use by military and security forces have an additional door built into the chassis of the mobile laboratory that leads from the outside in-to the Class III BSC.  This prevents the sample collector or person delivering the sample from having to enter the laboratory.  The number of doors and what they access is driven by the mission and user requirements.

HEPA Filtered Ventilated Pass Through Chambers

Based on requirements the user may also opt for having a HEPA filtered ventilated pass through chamber.  Ventilated chambers are commonly seen when a laboratory may receive a mixed sample that could contain a volatile chemical compound, but are also used when the pass through is the primary method of removing samples and other items from the Class III BSC that may not otherwise be removed via the dunk tank (animals in cages, plated samples, experiments that need to remain upright, etc).  Some users prefer the added safety of knowing the air in the chamber has been purged, and the pass through chambers exhaust system creates inward airflow upon opening the door to the lab.  Airflow varies with the airflow rate in the chamber of the BSC and the cubic volume of the interior of the pass through chamber.  Even if the chamber is ventilated, material leaving the Biological Safety Cabinet should be surface decontaminated and placed in a secondary container which is sprayed with decontaminant before being placed inside the pass through.  If a non-ventilated chamber is used, the same procedure as above can be followed with the addition of spraying the interior of the pass through chamber to facilitate the settling of any aerosols in the chamber. Whether ventilated or not, at the end of work, or upon a spill in the chamber, the pass through chamber must be decontaminated. 

 

 

Articles

  • BSL-3 Laboratory
  • Modular Laboratories
  • Mobile Laboratories
  • Gloveboxes
  • Class III Biological Safety Cabinets
  • Pharmacy Compounding Equipment
  • Compounding Aseptic Isolators
  • Compounding Aseptic Containment Isolators
  • Biological Safety Cabinets
  • Barrier Isolators

Events

  • The 2012 International Conference on Biocontainment Facilities
  • CBRNe Convergence
  • ABSA – 55th Annual Biological Safety Conference
  • ABSANZ 2nd Annual Conference
  • AGS Glovebox & Isolator Annual Conference & Trade Show
  • IFBA – Global Biosafety and Biosecurity
  • AfBSA African Biological Safety Association
  • 8th Symposium on CBRNE Threats
  • SIBB12 International Symposium on Biosafety and Biosecurity
  • The 7th A-PBA Biosafety Conference

Featured Product Lines

  • BSL-3 Facility Components
  • Class III Gloveboxes
  • Five Decades of R&D
  • Early Leader in High Containment
  • Furthering Advancements in Biosafety
  • Our Roots are in Research
  • 50 Years of Biosafety Innovation

Laboratory Safety Blog

  • GERMFREE recognized as VMA Exporter of the Year
  • Annual Field Testing for Certification of Class III BSC
  • International Performance Standards for Class III BSC
  • Article Outlines Rationale for Mobile Labs
  • BioContainment Equipment and Biosafety Training
  • US Performance Standards to Consult When Purchasing a Class III BSC
  • Pass Through Chamber Options in Class III BSC
  • Turbulent, Laminar and High Velocity Airflow in Class III BSC
  • Prefabricated HVAC Engineering Systems for BSL-3 Labs
  • Mobile and Deployable Class III BSC and Flexible Film Isolators

News

  • News Story Post 2
  • News Story Post 1

Pharmacy Blog

  • GERMFREE recognized as VMA Exporter of the Year
  • 2010 Joint Forces Pharmacy Seminar
  • NCPA 112th Annual Convention & Trade Expo.
  • FSHP Annual Meeting 2010
  • ASHP 45th Mid-Year Clinical Meeting
  • Welcome to the Pharmacy Blog
  • ASHP Summer Meeting and Exposition 2010
  • Pharmacy Blog

Press Release

  • Read more »

Product Lines

  • Portable Glovebox PGB-III
  • Ventilated Workstation
  • Advanced Engineering Capabilities
  • Through-Wall Embeds
  • LFGI Series
  • VersaFlow Series
  • Rapid Transfer Port
  • Gas Decontamination
  • Integrated Autoclaves
  • Environmental Test Chambers

Spotlight

  • More About: American Society of Health-System Pharmacists
  • More About: American Biological Safety Association
  • More About: American Glovebox Society
  • Germfree presents VWS in Bali

Text Ads

  • Mobile Laboratories
  • Modular Laboratory – keyword
  • Class III Biological Safety Cabinets – keyword
  • Gloveboxes Keyword
  • Pharmacy Compounding Equipment
  • Compounding Aseptic Isolators
  • Compounding Aseptic Containment Isolators
  • Biological Safety Cabinets
  • Barrier Isolators

Sorry, no posts matched your criteria.