• Home
  • Global Solutions
  • About Us
    • Events
    • Industry Resource Links
    • Product Articles
    • Spotlight
  • Contact Us
  • +1 (386) 265-4360, (800) 888-5357
Loading


Germfree

Just another WordPress site

  • Pharmacy Equipment
    • Compounding Aseptic Isolators
    • Radiopharmacy Equipment
    • Laminar Flow Hoods
    • Biological Safety Cabinets
    • Powder Containment Enclosures
  • Class III Biosafety Cabinets
    • Advanced Engineering
    • The SEA-III
    • Aerobiology
    • All Hazard Receipt
    • Mobile & Transportable
    • Total System Integration
    • Features & Options
  • Modular Labs
    • Modular Buildings
    • Containerized Modular
    • BSL-3 HVAC Mechanical Suite
  • Mobile Labs
    • Truck Laboratories
    • Van Laboratories
    • Trailer Laboratories
    • Mobile Container Labs
    • Air/C-130 Transportable
  • Custom Cabinets & Hoods
    • Custom Biosafety Cabinets
    • Custom Fume Hoods
    • Custom Laminar Flow
    • Ventilated Workstation
  • BSL-3 Components
    • Furniture
    • Autoclaves
    • Effluent Decontamination
    • Dunk Tanks
    • Airlocks
    • Through-Wall Embeds
    • Filter Systems
    • Gas Decontamination
    • Consulting
You are here: Home / Laboratory Safety Blog / US Performance Standards to Consult When Purchasing a Class III BSC

Class III BSC: Performance Testing Standards

There are several prominent industry accepted standards for performance testing of Class III Biosafety Cabinet in the US.  These standards contain some areas of overlap, and in many cases one standard contains performance related information not contained in the other standards.  The information below provides a brief summary of the highlights as they apply to criteria for US performance testing.  A subsequent blog will address international performance standards.

1. National Sanitation Foundation Standard 49, 2008:

  • It is a gas-tight (no leak greater than1x10-7 cc/sec with 1% test gas at 3 inches pressure wg) enclosure with a viewing window that cannot be opened without the use of tools or locks.
  • Access for passage of materials into the cabinet is through a dunk tank, that is accessible through the cabinet floor, or double-door pass-through box (e.g., an autoclave, rapid transfer port, pass through chamber)
  • Both supply and exhaust air are HEPA filtered on a Class III cabinet. Exhaust air must pass through two HEPA filters, or a HEPA filter and an air incinerator, before discharge to the outdoors.
  • Airflow is maintained by an exhaust system exterior to the cabinet, which keeps the cabinet under negative pressure (minimum of 0.5 inches of water gauge.)
  • The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facility ventilation system.

 2. American Glovebox Society, 2007 :

  •  Airflow monitoring: should be provided i.e. magnahelic guage
  • Differential pressure is industry specific: maintained at 0.2-1.5 inches wg
  • Glovebox flow rate through an open glove port: 125 +/- 25 linear ft/min
  • Glove inspections should be performed: no firm guidance on frequency
  • Leak detection: internal pressure is stabilized at -1.5 inches wg and temperature, pressure and time are recorded until pressure drops to -0.6 inches.  Leak rate can not exceed 0.5% glovebox volume per hour.
  • There should be qualified trainers and operator training.

3.  Laboratory Safety Monograph: A Supplement to NIH Guidelines for Recombinant DNA Research, 1979:

  • The Class III biological safety cabinet is a totally enclosed ventilated cabinet of gastight construction.
  • Class III cabinet is maintained under negative air pressure of at least 0.5 inches water gage. Supply air is drawn into the cabinet through HEPA filter. The cabinet exhaust air is filtered by two HEPA filters installed in series.
  • The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facility ventilation system.
  • Material transfer through double-door sterilizers and dunk baths with liquid disinfectants.
  • Should be certified (i) after a new cabinet has been purchased and installed, but before it is used, (ii) after it has been moved or relocated, and (iii) at least annually.
  • Negative pressure inches wg: >0.05
  • Leak tightness:  leak rate <1 x 10 -5 cc/sec at 3”wg pressure using halide tracer gas
  • Small leaks can be detected by soap solution testing
  • HEPA certification: annual or as needed above
  • Verify and calibrate magnahelic gauge and test audible alarm

Class III BSC:  Best Safety Practices & Engineering

Taken together there are a few recurrent points and statements that reflect best safety practices and engineering.  The Class III Biological Safety Cabinet must be leaktight (this implies very solid construction, durability and seals), and operate at -0.05 " wg relative to the lab.  Exhaust air is filtered through 2 HEPA filters in series, with supply air filtered by 1 HEPA filter.  Alarms should be present to warn the user of BSC failure, and the user should be trained in te correct operation of the unit.  The BSC and its HEPA filters should be field tested annually, but components that are prone to wear (i.e. gloves, gaskets, etc) should be inspected as part of a pre-operational inspection.  As perfromance tests in the field are not codified by NSF 49, recomendations on what types of field testing should be perfromed annually will be provided in a later blog.

References:

1. NSF 49 Class II (Laminar Flow) Biosafety Cabinetry, NSF/ANSI 49-2008,  Edition: 11th

2. Guideline For Gloveboxes, Third Edition AGS-G001, February 2007

3.  Laboratory Safety Monograph: A Supplement to the NIH Guidelines for Recombinant DNA Research, 1979 (PDF)

Articles

  • BSL-3 Laboratory
  • Modular Laboratories
  • Mobile Laboratories
  • Gloveboxes
  • Class III Biological Safety Cabinets
  • Pharmacy Compounding Equipment
  • Compounding Aseptic Isolators
  • Compounding Aseptic Containment Isolators
  • Biological Safety Cabinets
  • Barrier Isolators

Events

  • The 2012 International Conference on Biocontainment Facilities
  • CBRNe Convergence
  • ABSA – 55th Annual Biological Safety Conference
  • ABSANZ 2nd Annual Conference
  • AGS Glovebox & Isolator Annual Conference & Trade Show
  • IFBA – Global Biosafety and Biosecurity
  • AfBSA African Biological Safety Association
  • 8th Symposium on CBRNE Threats
  • SIBB12 International Symposium on Biosafety and Biosecurity
  • The 7th A-PBA Biosafety Conference

Featured Product Lines

  • BSL-3 Facility Components
  • Class III Gloveboxes
  • Five Decades of R&D
  • Early Leader in High Containment
  • Furthering Advancements in Biosafety
  • Our Roots are in Research
  • 50 Years of Biosafety Innovation

Laboratory Safety Blog

  • GERMFREE recognized as VMA Exporter of the Year
  • Annual Field Testing for Certification of Class III BSC
  • International Performance Standards for Class III BSC
  • Article Outlines Rationale for Mobile Labs
  • BioContainment Equipment and Biosafety Training
  • US Performance Standards to Consult When Purchasing a Class III BSC
  • Pass Through Chamber Options in Class III BSC
  • Turbulent, Laminar and High Velocity Airflow in Class III BSC
  • Prefabricated HVAC Engineering Systems for BSL-3 Labs
  • Mobile and Deployable Class III BSC and Flexible Film Isolators

News

  • News Story Post 2
  • News Story Post 1

Pharmacy Blog

  • GERMFREE recognized as VMA Exporter of the Year
  • 2010 Joint Forces Pharmacy Seminar
  • NCPA 112th Annual Convention & Trade Expo.
  • FSHP Annual Meeting 2010
  • ASHP 45th Mid-Year Clinical Meeting
  • Welcome to the Pharmacy Blog
  • ASHP Summer Meeting and Exposition 2010
  • Pharmacy Blog

Press Release

  • Read more »

Product Lines

  • Portable Glovebox PGB-III
  • Ventilated Workstation
  • Advanced Engineering Capabilities
  • Through-Wall Embeds
  • LFGI Series
  • VersaFlow Series
  • Rapid Transfer Port
  • Gas Decontamination
  • Integrated Autoclaves
  • Environmental Test Chambers

Spotlight

  • More About: American Society of Health-System Pharmacists
  • More About: American Biological Safety Association
  • More About: American Glovebox Society
  • Germfree presents VWS in Bali

Text Ads

  • Mobile Laboratories
  • Modular Laboratory – keyword
  • Class III Biological Safety Cabinets – keyword
  • Gloveboxes Keyword
  • Pharmacy Compounding Equipment
  • Compounding Aseptic Isolators
  • Compounding Aseptic Containment Isolators
  • Biological Safety Cabinets
  • Barrier Isolators

Sorry, no posts matched your criteria.