Menu
search

Radiopharmacy Biosafety Cabinets

Radiopharmacy Biosafety Cabinets

Protection Type: Product, Personnel, Environment
Industries: Biopharma, Healthcare
USP <825> Compliant
  • All Stainless Steel Design with Lead Shielding
  • Various Lead Thicknesses Available
  • USP 825 Compliant
  • Fits All Commercially Available Dose Calibrators
Request a quote

All stainless steel, lead shielded USP 825 compliant biosafety cabinet

Two things need protecting when you’re compounding radiopharmaceuticals: the product, from contamination, and the person doing the compounding, from exposure. The RADIOSAFE cabinet is built around that pairing. Continuous, unidirectional ISO 5 HEPA-filtered airflow keeps the work area clean, and inward airflow keeps that same air from ever reaching the operator. Each cycle, about 70% of it recirculates through the supply HEPA filter, and the remainder exhausts through a second HEPA filter, with an optional thimble connection for ducting outside. Class II Type A. USP 825 compliant. Built entirely from stainless steel.

Request a quote

Suitability

Protecting the product and the person preparing it, at the same time, is the whole job of compounding sterile radiopharmaceuticals. Germfree’s complete line of shielded isolators and biosafety cabinets is built for exactly that, available in Class 2 Type A or A2.

Applications

Radiopharmacy Biosafety Cabinets Specifications

Variations
White mechanical icon on green diamond
Overall dimensions
Model Width Depth Height
RADIOSAFE BSC 50" 27" 94"
White mechanical icon on green diamond
Work area dimensions
Model Width Depth Height
RADIOSAFE BSC 48" 27" 29"
White electrical icon on green diamond
Electrical

115 Volt, 60 Hz (220/50-60 Hz also available) 15 Amp (6 Run)

White light icon on green diamond
Lighting

Work area illuminated by externally-mounted light

White airflow icon on green diamond
Airflow

ISO 5/Class 100

White shielding icon icon on green diamond
Shielding

Front lifting viewing panel is easily removed and is gasketed to provide a proper seal when in place
Sliding leaded glass shield with 3/4” lead (13 3/4” x 20”)
Viewing window in shield is 8”x8”x4” with a density of 5.2g/cm3

White material icon on green diamond
Construction

Stainless Steel
Lead-lined dose calibrator housing (2” thick lead)
Lead on sides, back and bottom (3/4” thick)
Dose calibrator monitor arm

White pressure icon on green diamond
Air Pressure

Negative Air Pressure

White filter icon on green diamond
Filter

HEPA filtration

Talk to us about radiopharmacy biosafety cabinets

Contact us

Accessories

Swipe to view all accessories

Resources icon

Related resources

Germfree Radiopharmacy Biosafety Cabinet User ManualUser manual

Germfree Radiopharmacy Biosafety Cabinet User Manual

Germfree Radiopharmacy Biosafety Cabinet BrochureProduct Brochure

Germfree Radiopharmacy Biosafety Cabinet Brochure

Frequently Asked Questions

What is the RADIOSAFE biosafety cabinet designed for?

The RADIOSAFE cabinet is built for handling radiopharmaceuticals, protecting the product from contamination and the person compounding it from exposure at the same time. It’s Class II Type A, USP 825 compliant, and constructed entirely from stainless steel.

How does it protect both the product and the operator simultaneously?

ISO 5 HEPA-filtered laminar air holds the work area in continuous, unidirectional flow to keep the product clean, while inward airflow keeps that same space from ever reaching the operator. About 70% of the air recirculates through the supply HEPA filter every cycle, and the rest exhausts through a second HEPA filter, with an optional thimble connection for external ducting when needed.

What regulatory standards does it meet?

The cabinet is USP 825 compliant and operates under negative air pressure with HEPA filtration throughout.

What kind of lead shielding does it include?

The unit includes a sliding leaded glass shield with 3/4 inch lead, a lead-lined dose calibrator housing with 2 inch thick lead, and 3/4 inch lead on the sides, back, and bottom. Various lead thicknesses are available depending on your requirements.

Is it compatible with dose calibrators?

Yes, the cabinet fits all commercially available dose calibrators and includes a dedicated dose calibrator monitor arm.

What facility types and applications is it suitable for?

Germfree builds a complete line of shielded isolators and biosafety cabinets for compounding sterile radiopharmaceuticals, available as Class 2 Type A or A2, serving both biopharma and healthcare industries.

What accessories are available for the RADIOSAFE cabinet?

Available accessories include a stainless steel bin cart for transporting materials, a duplex electrical outlet installed in the work area, a sealed data port for passing cables into the cabinet while maintaining containment, a transition piece for external ducting, and a stopcock for controlling gases and liquids pumped into the cabinet.

When your mission calls for something custom, we deliver.

Some environments can’t take a catalog answer: the one-of-a-kind containment lab, the facility that has to survive shipment by military aircraft, the compounding pharmacy that has to stand up overnight. Tell us the constraints, we’ll build around them.

What You Can Count On

Proven Under Pressure

We take on the work that others won’t, and we see it through.

A Complete Capability

One team, accountable for the whole environment, design through service.

Beyond Delivery

Our relationships start before delivery and don’t end after it.

Built Around The Work

We shape the solution around your process, your site, and your use case, not the other way around.

Contact us: Let's deliver on your mission together

Complete our contact form and a member of our commercial team will reach out to you within 24 hours.
Service & support: cs@germfree.com

Send us your request