Custom, Portable and Transportable Class II Biosafety Cabinets

Custom Class II for Biopharmaceutical & Laboratory Applications

GermFree Custom Class II BSC PP, bsc, biological safety cabinetThe Class II Laminar Flow Biological Safety Cabinet (BSC) combines product, operator, and environmental protection.

Class II BSCs are utilized for containing low to moderate risk biohazardous materials. These units provide downflow HEPA filtered air to protect the product, along with HEPA filtered exhaust air to safeguard the working environment from particulate and aerosol hazards.

 

Alert1 SAFETY WARNING:
Class II BSCs are designed to handle low to moderate risk material and should never be used for high-risk or unknown materials.

For higher containment applications please see our line of Class III BSC Gloveboxes. We offer a full range of Custom Class III Biological Safety Cabinets and Pharmaceutical Isolators.

 

Custom Class II Biological Safety Cabinets

The laminar flow Class II Biological Safety Cabinet is designed to provide personnel and environmental protection from the hazards of particulates and aerosols generated by the handling of low- to moderate-risk solids and liquids. Class II BSCs also provide protection for the product on or above the work surface via continuous flow of ISO Class 5/Class 100 air.

Class II Biological Safety Cabinets can be specially designed to accommodate all sizes of laboratory equipment and are appropriate for a range of laboratory settings. In addition to biological research and pharmacy applications, these hoods are also used in industry for the safe handling of dust and powders.

Class II, Type A Biosafety Cabinets – BBF Series

Class II, Type A BSCs are used for personnel and environmental protection from bio-aerosols and other particulates, as well as for product prote

ction. To protect the product, the work area is bathed with a continuous stream of ultra-clean air, which is provided through the supply HEPA filter. Approximately 70% of the air from each cycle is recirculated through this supply HEPA filter.

Although not required for the majority of uses, all of our Class II Type A Biological Safety Cabinets have the capability of being vented to the outside environment via a canopy, or “thimble,” connection.

bbfairflow, biological safety cabinet, bsc

Class II, Type B2 Biological Safety Cabinets – BTE Series

The Class II Type B2 Biosafety Cabinet has no recirculation of air into the cabinet. It is a total exhaust, non-recirculating, vertical laminar flow biological safety fume hood.

Germfree’s Class II, Type B2 Cabinets augment the level of protection delivered by a conventional fume hood and a Class II, Type A Biosafety Cabinet by venting 100% of the air entering the hood to the outside. This total exhaust feature makes the B2 Biosafety Cabinet suitable not only for controlling particulates, but also for containment and filtration of fumes and gases.

Class II, Type B2 BSCs are especially appropriate for work with radionuclides, effluents from subliming particulates, and noxious odors.

bteaiflow, biological safety cabinet, bsc

The Class II Type B2 Biological Safety Cabinet was developed by Germfree to provide personnel and environmental protection from diverse types of biohazardous materials as well as from the gases and fumes that are a common by-product of biological work.

Germfree invented and patented the Total Exhaust Biological Safety Cabinet, which was later classified as a Class II B2 Cabinet.

Read more about Validation Services offered by Germfree.

Read more about the types and classes of biological safety cabinets Germfree creates.