EPD number : SCS-EPD-09487 Category ISO 21930:2017
Home / Arcoplast / Resources / Acryloyl resources
Acryloyl resources
Certifcations
EPD number : SCS-EPD-09487 Category ISO 21930:2017
Living Building Challenge. LBC 4.0
Logistical economic environmental footprint
Compliance
Standards
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
CSI
NYC Building Toxicity
Seismic
VOC
Dimensions
Quick links
ACRYLOYL 6.3 mm : Lining panel
Thickness: 1/4 inch (6.3 mm)
Width: 4ft | Tolerance +/- 1/16 inch (1200 mm | Tolerance +/- 1.5 mm)
Length: 3 – 16 ft | Tolerance +/- 1/2 inch (900 – 4875mm | Tolerance +/- 12.5 inch)
Weight: 2.0 Lbs / Sq. Ft (9.7 Kg/M2)
Joint Profiles
End Cut
Side Edge
Joint System
Application : Wall and ceiling cladding system for new, or modernizing existing cleanrooms
Dry Build : Direct attachment to framing or substrate, using back plates and A-2020 structural adhesive
Rated : BSL-2, BSL-3, ABSL-3, BSL-3Ag
ACRYLOYL 9.5 mm : High containment panel
Thickness: 3/8 inch (9.5 mm)
Width: 4ft | Tolerance +/- 1/16 inch (1200 mm | Tolerance +/- 1.5 mm)
Length: 3 – 16 ft | Tolerance +/- 1/2 inch (900 – 4875mm | Tolerance +/- 12.5 inch)
Weight: 3.5 Lbs / Sq. Ft (17.09 Kg/M2)
Joint Profiles
End Cut
Side Edge
Joint System
Application : Wall and ceiling cladding system for new, or modernizing existing cleanrooms
Dry Build : Direct attachment to framing or substrate, using back plates and A-2020 structural adhesive
Rated : BSL-2, BSL-3, ABSL-3, BSL-3Ag
Documents
Quick links
Brochures
BH-2A : Acryloyl chemical stain resistance
BH-5A Side by side Acryloyl & GFRP
BH-7A : Engineered Polymer panels
Dry Build Overview
ED 001 Design considerations interactive PDF
ED 002 Acrobat Quick-keys : Mac and PC presentations
Documents: CSI. SDS.
CSI-SECTION 068315 : Acryloyl Wall Ceiling panels.
SDS-190301 Safety data. March 1 2019
Technical documents
TK-1 : Wall & Ceiling Panel systems
TK-2 : Arcoform protective shroud systems
PRV-01 : Structural peer review B2004610
Installation manuals
IM-4 Acryloyl Installation manual V3. Oct 5 2022
VID-2 Installation video
Volumes
VOL-1 Science of sealants, adhesives & penetrations
VOL-2 Science of primary barriers
VOL-3 The Science of Seismic Design
Drawings
Quick links
Acryloyl panels: 6mm
Walls & ceilings : attached to framing
PNL-4ep : 6 mm Square edge panel detail
PP-59ep : Joint. Wall/ ceiling panel, batten cover strips
PP-34ep : Joint. Wall/ ceiling panel over gypsum
PP-44ep : Joint. Wall/ ceiling panel over steel framing
PP-35ep : Inside corner. Wall/ ceiling panel over gypsum
PP-36ep : Inside corner. Wall to wall over gypsum
PP-37ep : Outside stainless corner guard over gypsum
Walls & ceilings : attached to substrate
BA-20ep : Base joint. 6mm panel to finished floor joint
CDA-5ep : Flush joint, over IMP substrate
PP-43ep : Panel joint over existing conditions
PP-52ep : Inside corner. Wall to wall over concrete block
SPL-15 : Stainless J channel, detail
Acryloyl panels: 9.5 - 12.5mm
BASE. Wall to floor : attached to framing
BA-1ep : Base joint, zinc strip termination
BA-2ep : Base joint, zinc strip termination over gypsum
BA-9ep : Base joint, zinc strip termination, vinyl floor
BA-3ep : Base joint, termination no zinc strip, mono floor
SPL-14 : Zinc termination strip, detail
BA-4ep : Base backer joint flush to panel, monolithic floor
BA-5ep : Base backer joint. Panel over gypsum, mono floor
SPL-16ep : Panel flush to floor base. J Spline detail
BA-17ep : Panel flush to floor base. Laminated wall
PP-12ep : Panel flush to floor base. Monolith floor curb
BA-15ep : Panel flush to concrete floor curb
BA-14ep : Panel to concrete floor curb
BASE. Wall to floor : attached to substrate
BA-7ep : Base joint over rigid insulation, existing conditions
BA-6ep : Base joint. Panel to monolithic floor covering
BA-13ep : Base joint. Panel to finished floor joint
CONNECTING. Panel to panel : attached to framing
PNL-1ep : 9.5mm Panel. Detail kerf with spline
SPL-5 : 9.5mm Seismic spline, detail
PNL-2ep : 12.5mm Panel. Detail, kerf with spline
CDA-1ep : Spline assembly. Ceiling panel
CDA-2ep : Spline assembly. Ceiling panel over gypsum
PP-1ep : Spline assembly. Wall panel
PP-30ep : Spline assembly. Insulated wall panel
PP-4ep : Wall partition fitted with SAFB
PP-5ep : Wall partition over gypsum, fitted with SAFB
PP-49ep : Wall partition, gypsum outer layer, with SAFB
CORNER. Wall to wall : attached to framing
PP-13ep : Inside corner assembly
PP-20ep : Outside corner, stainless corner guard
CORNER. Wall to wall : attached to substrate
PP-14ep : Inside corner detail. Existing structure
PP-53 : Outside corner. Hat furring. Existing condition
PP-31ep : Wall partition to existing gypsum wall frame
CORNER. Wall to ceiling : attached to framing
CDA-11ep : Inside corner. Acryloyl ceiling, gypsum wall
PP-32ep : Wall partition to existing gypsum ceiling
CORNER. Wall to ceiling : attached to substrate
PP-11ep : Inside corner. Spline joint to existing conditions
CDA-10ep : Inside corner. Spline joint to masonry
Acryloyl : specialized panels
Acryloyl ultra 19mm : high impact panel
PNL-3ep : 19mm Ultra. High impact panel
Acryloyl : partition system
CDA-9ep : Ceiling mount. Ceiling panel to laminate covering
PP-39 : Non metallic orchestrate framing
AD-8 : Removable floor, ceiling, panel attachment detail
PP-10ep : Wall partition. Wall to floor connection
BA-11ep : Wall partition, wall to floor connection, flush base
Doors, Glazing, Penetrations & Windows
Door frame
DF-1ep : Door frame sealed detail. Typical jamb
DF-2ep : Door frame seal flush W/Wall finish
DF-3ep : Door frame seal flush W/Wall jamb head
DF-4ep : Door frame seal flush W/floor jamb head
DF-5ep : Door frame seal flush floor base detail
DF-6ep : Door frame, flush floor base jamb. Masonry
DF-11ep : Full Glass stainless door frame & jamb
DF-13ep : Full Glass stainless door frame & jamb
DF-14ep : Flush door frame seal with wall, typical jamb
DF-16ep : Primary barrier- flush cGMP finish
DF-17ep : Primary barrier- flush cGMP finish
DF-18ep : AL door frame flush with wall finish
DF-19ep : AL recessed door frame (CGMP)
DF-21ep : Door frame, stainless guard, existing conditions
Housing window systems
WF-3ep : AL frame, double glaze, weep holes, dual wall
WF-6ep : AL frame, wall panel one side
WF-14 : AL frame & mullion, single glaze
WF-9ep : Double glazing. Acryloyl panel one side of wall
WF-10ep : Double glazing. Dual wall Acryloyl 12.5mm wall
WF-13ep : AL frame, Acryloyl one side of wall. Wall corner
WF-15ep : AL frame, double glaze, dual gypsum wall
WF-17ep : AL frame. Wall panel each side
WF-5 : AL frame, mullion installation procedure
WF-1 : Fiberglass frame, Acryloyl panel
WF-2 : Internal glazing, wall installation
WF-10 : Stainless frame, double glaze, dual wall
WF-12 : Stainless frame, Acryloyl panel over IMP
Penetrations
P-1 : Electrical duplex installation
P-6 : Cable & wiring, penetration installation
P-4 : Conduit or piping penetration installation Part 1
P-9 : Conduit or piping penetration installation part 2
P-5 : Concealed sprinkler head penetration installation
S-1 : Counter top shelving attachment detail
S-2 : Counter top shelf bracket attachment detail
P-19 : HEPA style filter, mounting detail
P-3 : HVAC duct penetration installation
P-8 : HVAC grille penetration
P-7 : Light fixture recessed, installation procedure
P-14 : Light fixture, surface mount penetration
P-11 : Oval round penetration
P-13 : Rectangle, square grille penetration
P-10 : Rectangle, square penetration procedure
P-17 : Room pressure monitor box installation
P-12 : Stainless pass through sleeve penetration part 1
P-18 : Stainless pass through sleeve penetration part 2
P-15 : Surface mounted equipment part 1
P-15 : Surface mounted equipment part 2
Window glazing systems
W-1 : Al frame window detail 2'-0" x 3'-4"
W-1a : Al frame window detail 2'-6" x 6'-10"
W-2 : Al frame window detail 3'-0" x 3'-4"
W-2a : Al frame window detail 3'-4" x 4'-2"
W-3 : Al frame window detail 3'-0" x 5'-0"
W-4 : Al frame window detail 4'-0" x 5'-0"
W-5 : Al frame window detail 1'-6" x 4'-0"
WS-1 : Al frame window detail 1'-0" x 4'-0"
WS-1.6 : Al frame window detail 1'-6" x 4'-0"
WS-2 : Al frame window detail 2'-0" x 4'-0"
WS-2.6 : Al frame window detail 2'-6" x 4'-0"
WS-3 : Al frame window detail 3'-0" x 4'-0"
WS-3.6 : Al frame window detail 3'-6" x 4'-0"
WS-4 : Al frame window detail 4'-0" x 4'-0"
WS-4.6 : Al frame window detail 4'-6" x 4'-0"
WS-5 : Al frame window detail 5'-6" x 4'-0"
WS-5.6 : Al frame window detail 5'-6" x 4'-0"
WS-6 : Al frame window detail 6'-4" x 4'-0"
Summary
Quick links
Barrier tests conducted using 12.5mm acryloyl
| Result | Test | Description |
|---|---|---|
| Pass | ASME N510 | Air pressure decay nuclear air treatment systems test |
| Pass | MEP test | Air pressure decay nuclear air treatment systems test |
| Pass | Test | Air pressure decay test on expansion joint & electrical face plates test |
| Pass | Test | Air pressure decay test on screw penetrations test |
| Pass | BSL-3, BSL-4 | Air pressure decay test small chamber BSL-3, BSL-4 test |
| Pass | Test | Supplemental helium leak testing |
| Pass | Report | Window panel pressure decay test report |
Color surface tests conducted using 12.5mm Acryloyl
| Result | Test | Description |
|---|---|---|
| Pass | ISFA 2-01 | Arcoplast cleanability & stain resistance |
| Pass | ASTM D 1308-02 | Arcoplast surface and sealant chemical compatibility |
| Pass | ISO 2812-4 | Arcoplast surface and sealant chemical compatibility |
| Pass | Coloration | Chlorine dioxide decontamination procedure |
| Pass | Coloration | Formaldehyde gas decontamination procedure |
| Pass | Coloration | Hydrogen peroxide vapor decontamination procedure |
| Pass | UV test | Exposure cycles |
Fire & smoke tests conducted using 12.5mm Acryloy
| Result | Test | Description |
|---|---|---|
| B-s1-d0 | EN 13501-1 – Europe, Asia | Classification of reaction to fire performance, in accordance with – Europe, Asia |
| Pass | ISO 9705 Annex B | Full scale room fire test |
| MEA 64-96-M | UPITT Protocol Toxicity Test | Measurement of acute lethality decomposition products |
| 10.8 FS - 6.1 SD | UL S-102 Test | On surface burning characteristics (Must be on full composite construction – Canada) |
| 10 FS - 0 SD | ASTM E-84 Test | On surface burning characteristics (Must be on full composite construction – USA) |
| Pass | UL 94 – 5VA 500W | Vertical burning test |
Microorganism tests : Acryloyl panels
| Arcoplast Wall and Ceiling Systems | Test : ISO 846 |
|---|---|
| SCOPE: International Standard ISO 846 is used to determine the deterioration of plastics due to action microorganisms. | |
| CONCLUSION: Resist to fungi and bacteria, does not support microbial growth. Results obtained conclude, test sample does not provide any nutrition for bacteria and fungi. Acryloyl panel surfaces (face and back side) resist fungi and bacteria and does not support microbial growth. | |
| Arcoplast Wall and Ceiling Systems | Test : ASTM D3273-00 |
|---|---|
| SCOPE: To test the resistance of test samples to mold growth. | |
| CONCLUSION: Products tested were effective in preventing fungal growth, were found to be resistant to fungi tested. Acryloyl panel surfaces (face and back side) were effective in preventing fungal growth. All samples had an ASTM D3273 rating of 10. | |
| Arcoplast Wall and Ceiling Systems | Test : ASTM D3274-09 |
|---|---|
| SCOPE: To test the resistance of test samples to mold growth. | |
| CONCLUSION: Products tested showed 0% coverage of fungal growth. All samples had ASTM D3274 rating of 10. | |
Physical tests: Acryloyl 12.5 mm
| Result | Test | Description |
|---|---|---|
| Pass | MEA 414-04-M | City of New York Department of Buildings |
| Pass | US FDA 21 CFR 177.2600 | Determination of Extractives Residue according to US FDA |
| Pass | LBC 3.1 | Living Building Challenge 3.1 |
| Pass | CSI 3-Part Format | Product Guide Specification Written According To CSI 3 |
| Pass | Compliant test | USDA, FDA, NIH, CDC, NIAID, CANADA AGRICULTURE Compliant |
Surface tests conducted using 12.5mm Acryloyl
| Result | Test | Description |
|---|---|---|
| Pass | ISFA 2-01 | Arcoplast cleanability & stain resistance |
| Pass | ASTM D 1308-02 | Arcoplast surface and sealant chemical compatibility |
| Pass | ISO 2812-4 | Arcoplast surface and sealant chemical compatibility |
| Pass | Coloration | Chlorine dioxide decontamination procedure |
| Pass | Coloration | Formaldehyde gas decontamination procedure |
| Pass | Coloration | Hydrogen peroxide vapor decontamination procedure |
| Pass | UV test | Exposure cycles |
Surface topography
| Surface Topography | Acryloyl |
|---|---|
| Ra* : Roughness Average | 0.020 μm |
| Rq : Roughness, root mean square average | 0.03 μm |
| Rz : Average Maximum Height of the Profile | 0.16 μm |
| Rp : Maximum Profile Peak Height | 0.09 μm |
| Rv : Maximum Profile Valley Depth | 0.07 μm |
| Rt : Maximum Height of the Profile | 0.21 μm |
Tests
Quick links
Barrier
BR-1 Air pressure decay : Acryloyl panel
BR-1a Air pressure decay: MEPs
BR-1b Air pressure decay : Screw penetrations
BR-1c Air pressure vacuum decay
RF Attenuation. Acryloyl test report : G105789756grr166
VOC. Acryloyl test report : V1NNW211GC-Rev.
Color
CLA-1 Chemical durability cleaning solvents
CLA-2 Series of panel exposure tests
Fire & smoke
FSA-1 : ISO 11925-2 Reaction to fire
FSA-2 : ISO 9705 Full scale room fire
FSA-3 : ASTM E84 Surface burning
FSA-3a : CAN/ULC-S102-10 Surface Burning
Mechanical test
MTA-1 : Interior corner peel strength
MTA-2 : Load unit conversion
MTA-3 : Pull out strength various fasteners
MTA-4 : Partition assembly test
MTA-5 : Seismic shear lateral strength
MTA-5a : Seismic shear load strength
Sound
SDA-1 : ASTM E90-09/E413-10 Sound transmission
Strength
SRA-1 : Mil 1073.2 Ball drop test
SRA-2 : ASTM D2583-07 Barcol indentation
SRA-3 : ASTM D696-03 Coefficient linear expansion
SRA-5 : ASTM D790-15 Flexural strength
SRA-6 : ASTM D638-14 Tensile properties
Surface
SFA-1 : ISO 846 Resistance fungus
SFA-2 : ASTM D3274-09 Resistance mold
SF-3 : ASTM D523-14 Specular gloss
TPG-L-1966 : Topography surface
L-8483e : Topography surface
SFA-5a : D570-98 Water absorption
SFA-5b : ASTM E 96 Water vapor permeance
Connect with our Arcoplast team
Complete our contact form and a member of our commercial team will reach out to you within 24 hours to discuss Arcoplast.