Mobile Clinical Laboratories
Mobile Clinical Laboratories for point of care testing
Mobile Clinical Laboratories bring testing services to the patient in an efficient, modern, 450 sq ft high throughput facility. This rapidly deployable & compliant facility is used by our clients for standard diagnostics lab testing, clinical research, genomics testing, pre-clinical and analytics development.
Product highlights
Healthcare, Biopharma, Biocontainment
BSL-2, CLIA Compliant
Built to enable mobile clinical laboratory testing capacity anywhere
Germfree’s bioGO (R) mobile biocontainment facilities are designed and built in accordance with the CLIA guidelines for clinical laboratories and also meet CDC NIH BMBL guidelines for BSL-2 laboratories.
The primary use of our mobile clinical laboratories is to provide diagnostic and clinical laboratory capacity to remote regions, areas needing constant facility movement, or clients needing surge capacity to meet demand. Our platform allows your business to collecting samples quickly and analyzing them in a full scale 450 sq ft mobile laboratory. This platform is also an effective way to minimize the risks associated with testing by keeping samples isolated from the main facility.
- Rapidly deployable and movable
- All HVAC and MEP included
- Serviced and maintained by Germfree
- CLIA Clinical Laboratory Compliant
- Integrates with existing facility
- 100% Standalone, Freestanding Facility
Explore mobile clinical laboratory features

Mobile Clinical Lab Layouts
Explore our standard facility layouts that cover a broad range of applications and process flows. If these do not meet your application needs, learn more about our custom solutions.
Mobile Clinical Laboratory Layout
Mobile Clinical Laboratory Layout
The room classifications of this facility flow from the entryroom into the adjoining anteroom and into the main BSL-2 classified recirculating analytical testing/diagnostics suite.
Looking for something custom?
We have deployed research facilities for shipment by military aircraft, designed equipment to contain the most dangerous agents on the planet, produced facilities to manufacture lifesaving medicines and mobilized hospital compounding during times of regulatory change. Connect with Germfree experts to unlock your scientific potential.
Specifications
Room Classifications
- Negative Pressure Anteroom, Negative Pressure BSL-2 compliant lab suite
Mechanical
- 450 sq ft, 53′ Feet Long – Free standing with fully integrated HVAC and MEP to perform in any region
- HVAC is bio-decontamination compatible – Separate mechanical space
Electrical
- Internal power connection, dedicated backup panels for critical facility infrastructure
- NFPA 70 NEC 2020 Compliant
Plumbing
- Ready to accept site tepid and cold water supply
Door Controls
- Wave to open door controls with configurable interlocks and timing
Building Management System
- A central BMS controls all aspects of the facility via BACnet communication protocols
- BMS is designed to limit single point vulnerability
- Contains an operator interface inside with various operator levels
- BMS is compatible with local control outputs for override, emergencies, and testing
- Visual and audible alarm system
Architectural
- Seamless 40′ Arcoplast walls
- Finishes are durable against harsh cleaning agents such as sporicidal agents and VHP
- Every build prioritizes a sealed, cleanable, and leak free interior envelope
Security, Access, Fire & Data
- CFR Compliant CCTV with 1TB storage system
- 4 internal cameras
- 4 external cameras
- Fire & burglar alarm
- Unique code personnel access control
- Intercom system for in-lab communication
- Optional: Key Card Access
Site Requirements
- Concrete or Dirt Parking lot with < 3% grade
- Fresh and Grey Water Connections
- Utility Connections, Staff Access, Site Security
Integrated Process Equipment
- Active, HEPA-purging 100% stainless steel material pass through for an optimized material flow
- 100% stainless steel casework, designed for mobile applications with optimal cleanability & durability
- Class 2 BSC or Laminar Flow Workstation – Optional: Gowning benches, shelving & storage
Gas Piping
- Gas manifolds to accept a variety of gases. (co2,o2,n2, & compressed air for example)
- Oxygen cleaned piping to minimize potential contaminants, 316L Stainless Steel, ASME-BPE Compliant
Types of Equipment Add-Ons
The Germfree difference
Factory Acceptance & Site Acceptance Testing
Mobile clinical laboratories undergo stringent testing protocol to meet CLIA and BSL2 standards. Our facilities are factory acceptance tested before shipment and site acceptance tested onsite before final handover to the client.
Project Management
We manage all complexities associated with your project: site infrastructure audits, documentation submittals for certification, installation, equipment manufacturing & procurement, engineering and more.
Support & Maintenance
Germfree’s service team supports facilities 24/7, providing preventative monitoring, diagnostics and maintenance worldwide.
Flexible Ownership Options
Our mobile clinical laboratory’s can be deployed from Germfree instantly via our lease fleet and made operational in a matter of hours.
Related insights
Related resources
Contact us: Let's unlock your scientific potential together
Complete our contact form and a member of our commercial team will reach out to you within 24 hours.
Sales: + 1 (386) 265-4300
Service & support: cs@germfree.com
Send us your request